Designed to reach very high speeds, IMATIC dedicates more time to the most delicate phases of the filling process. The continuous movement of the unique turret system has proven over the years to combine precision and reliability.
Designed to reach very high speeds, IMATIC dedicates more time to the most delicate phases of the filling process. The continuous movement of the unique turret system has proven over the years to combine precision and reliability.
Able to dose powder or pellet into hard gelatine capsules, the IMATIC operating system is based on a single turret concept where a rotary motion of 810 degrees guides the capsules through all processing phases.
A large number of pharma companies are looking into energy consumption optimisation by using reduction and recovery strategies.
The innovations in washing technology can improve water consumption throughout the various steps of the cleaning cycle.
IMATIC water recirculation system allows consumption saving and reduces the disposal of dirty water at the end of the washing cycle, while granting optimal equipment performance.
TECHNICAL DATA IMATIC | ||
Model | IMATIC 100 | IMATIC 150 |
Number of stations | 24 | 36 |
Maximum speed (capsules/hour) | 100,000 | 150,000 |
Sizes processed | 000-5-Supro A-E, DB, DB.AA, vegicaps: vegetable capsules | |
Maximum installed power (kW) | 37 | |
C.I.P. skid power (kW) | 6 | |
Standard voltage | 230/400 V – 3F – 50/60 Hz | |
Aspiration | 9,500 litres/minute 3,200 mm H₂O | |
Compressed air | 30 m³/h – 6 bar | |
Vacuum (m³/h) | 100 + 65 | |
Weight (kg) | 3,000 |