As an alternative to the IMA LIFE fully automatic robotic opening of sterile RTU primary packages, handling of primary materials can be either performed semi-automatically or in part manually.
As an alternative to the IMA LIFE fully automatic robotic opening of sterile RTU primary packages, handling of primary materials can be either performed semi-automatically or in part manually.
Using a semi-automatic procedure, the gloved operator places the sealed package on the cutting station. The overbag is then automatically cut and the tub/tray is automatically pushed out of the bag without being touched, and transferred to the sterile area through an automatic gate. The overbag is removed manually and disposed of by the operator using gloves.
The partially manual procedure involves the operator, again using gloves, placing the sealed package on the cutting station. After positioning the overwrapped tub/tray on the cutting station, using gloves, the operator performs the cutting operation manually and subsequently pushes the tub/tray gently onto a sloped chute towards the separate processing area, taking care to remove and dispose of the overwrapped bag.
After cutting, the package is instantly transferred via an internal transfer port to the isolated processing area where the tub/tray will be definitively opened at the de-lidding station.
PRIMARY PACKAGE | RTU SYRINGES | RTU CARTRIDGES | RTU VIALS |
BAG TYPE | SINGLE / DOUBLE BAG | ||
BAG MATERIAL | PLASTIC | ||
BAG SIZE | ALL | ALL | ALL |
TUB SIZE | ALL | ALL | – |
TRAY SIZE | – | – | ALL |